Welcome to the Refreshed Webstore!Click for more details.
 

Conductivity Standard Cole-Parmer 150000US 16oz

SKU
CP/P-00652-56
Brand
COLE-PARMER
Pre-order (Deliver in 8 to 12 weeks)
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

KEY FEATURES

  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 150,000 �S/cm

MORE ABOUT THIS ITEM

-Oakton Traceable conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C�convenient!!
-Average accuracy at 25°C is �0.25 microsiemens for 1, 5, 10 microsiemen (�S) solutions, or �0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 �S/cm
-Individually-tested solutions are certified by the bottle�each bottle is analyzed for the best accuracy

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable�Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for�A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable�Certificate is supplied to indicate traceability to standards provided by�NIST�(National Institute of Standards and Technology) and/or a National Standards Laboratory.�A2LA�accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy.�Conductivity Standards are produced in an�A2LA�accredited�ISO/IEC 17025:2005 (1750.01)�calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

Specifications & Description

  • Conductivity Value (�S)150000
  • Conductivity Value (mS)150
  • TDS Value (ppm)100000
  • Volume (mL)500
  • Volume (oz)16
  • DescriptionTraceable Conductivity and TDS Standard, Individually-Tested, 150,000 �S; 500 mL
Login For Price
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

KEY FEATURES

  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 150,000 µS/cm

MORE ABOUT THIS ITEM

-Oakton Traceable conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C—convenient!!
-Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 µS/cm
-Individually-tested solutions are certified by the bottle—each bottle is analyzed for the best accuracy

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Conductivity Standards are produced in an A2LA accredited ISO/IEC 17025:2005 (1750.01) calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

Specifications & Description

  • Conductivity Value (µS)150000
  • Conductivity Value (mS)150
  • TDS Value (ppm)100000
  • Volume (mL)500
  • Volume (oz)16
  • DescriptionTraceable Conductivity and TDS Standard, Individually-Tested, 150,000 µS; 500 mL
More Information
Brand COLE-PARMER
Write Your Own Review
You're reviewing:Conductivity Standard Cole-Parmer 150000US 16oz
Your Rating
Who Viewed This Also Viewed
  1. W.L. NUTRIENT AGAR 500 grams/bottle
    W.L. NUTRIENT AGAR 500 grams/bottle Brand: CONDALAB SKU: CDL/1086
    Login For Price
  2. K.A.A. CONFIRMATORY AGAR 500 grams/bottle
    K.A.A. CONFIRMATORY AGAR 500 grams/bottle Brand: CONDALAB SKU: CDL/1027
    Login For Price
  3. ML204T/30243397 Mettler Toledo ML-T series Analytical Balance,220g/0.1mg+IP54 protection with
    ML204T/30243397 Mettler Toledo ML-T series Analytical Balance,220g/0.1mg+IP54 protection with Brand: METTLER TOLEDO SKU: MT/ML204T
    Login For Price
  4. Mini UniPrep Syringeless Filter, 0.2µm PTFE  100/pk
    Mini UniPrep Syringeless Filter, 0.2µm PTFE 100/pk Brand: WHATMAN SKU: WH/UN203NPEORG
    Login For Price
  5. No. 3 Filter Circles 24cm/100
    No. 3 Filter Circles 24cm/100 Brand: WHATMAN SKU: WH/MA/AO/1003240
    Login For Price