Welcome to the Refreshed Webstore!Click for more details.
 

Standard Cole-Parmer 100000US

SKU
CP/OO/O/P-00652-72
Brand
COLE-PARMER
Pre-order (Deliver in 8 to 12 weeks)
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 100,000 �S/cm

Specifications & Description

  • Conductivity Value (�S)100000
  • Conductivity Value (mS)100
  • Conductivity Value100,000 �S/cm
  • TDS Value (ppm)66666
  • Volume (mL)100
  • Volume (oz)3.4
  • Volume6 x 100 mL vials
  • Description Oakton Traceable One-Shot� Conductivity and TDS Standard, 100,000 �S; 6 x 100 mL Vials

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

KEY FEATURES

  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 100,000 �S/cm

MORE ABOUT THIS ITEM

-Oakton Traceable One-Shot� conductivity and TDS standards include detailed KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C�convenient!!
-Average accuracy at 25°C is �0.25 microsiemens for 1, 5, 10 microsiemen (�S) solutions, or �0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 �S/cm
-Batch-tested solutions are lot certified; a few bottles from a single lot are analyzed

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable�Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for�A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable�Certificate is supplied to indicate traceability to standards provided by�NIST�(National Institute of Standards and Technology) and/or a National Standards Laboratory.�A2LA�accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy.�Conductivity Standards are produced in an�A2LA�accredited�ISO/IEC 17025:2005 (1750.01)�calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

Login For Price
Traceable conductivity standards are Certified Reference Materials, making one of the most accurate available
  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 100,000 µS/cm

Specifications & Description

  • Conductivity Value (µS)100000
  • Conductivity Value (mS)100
  • Conductivity Value100,000 µS/cm
  • TDS Value (ppm)66666
  • Volume (mL)100
  • Volume (oz)3.4
  • Volume6 x 100 mL vials
  • Description Oakton Traceable One-Shot™ Conductivity and TDS Standard, 100,000 µS; 6 x 100 mL Vials

INCLUDES

temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.

KEY FEATURES

  • All Oakton Traceable conductivity standards are NIST-traceable reference materials
  • Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
  • These standard solutions let you calibrate conductivity instruments to ensure accuracy
  • If unopened, shelf life is one year; once opened, shelf life will vary by solution value
  • Use when readings are expected to be around 100,000 µS/cm

MORE ABOUT THIS ITEM

-Oakton Traceable One-Shot™ conductivity and TDS standards include detailed KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C—convenient!!
-Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (µS) solutions, or ±0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
-Conductivity options range from 1 to 200,000 µS/cm
-Batch-tested solutions are lot certified; a few bottles from a single lot are analyzed

METHODS SUPPORTED
-Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.

A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
-To assure accuracy an individually serial-numbered Traceable Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Conductivity Standards are produced in an A2LA accredited ISO/IEC 17025:2005 (1750.01) calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).

More Information
Brand COLE-PARMER
Write Your Own Review
You're reviewing:Standard Cole-Parmer 100000US
Your Rating
Who Viewed This Also Viewed
  1. Uniflo 2, 13mm PTFE 0.22µm 500/pk
    Uniflo 2, 13mm PTFE 0.22µm 500/pk Brand: WHATMAN SKU: WH/99111302
    Login For Price
  2. 15,000 uS Cond. Sachets, 20x20ml/box (ECCON15000BS) (01X219904)
    15,000 uS Cond. Sachets, 20x20ml/box (ECCON15000BS) (01X219904) Brand: EUTECH SKU: EU/SO/CO/CON-15000BS
    Login For Price
  3. General purpose fume cupboard Cr1200FC-P
    General purpose fume cupboard Cr1200FC-P Brand: CHEMORESOURCES SKU: CRM/CR1200FC-P
    Login For Price
  4. Mettler Toledo Stainless Steel Individual Weight, OIML Class F1, 1Kg
    Mettler Toledo Stainless Steel Individual Weight, OIML Class F1, 1Kg Brand: METTLER TOLEDO SKU: MT/30402664
    Login For Price
  5. Sealing Mat for DWP 96/2000, 50 pcs
    Sealing Mat for DWP 96/2000, 50 pcs Brand: EPPENDORF SKU: EP/0030127960
    Login For Price